CMS Pub. 100-03, ch. 1, § 20.8.1
Cardiac Pacemaker Evaluation Services
Medicare covers a variety of services for the post-implant follow-up and evaluation of
implanted cardiac pacemakers. The following guidelines are designed to assist A/B
MACs in identifying and processing claims for such services.
NOTE: These new guidelines are limited to lithium battery-powered pacemakers,
because mercury-zinc battery-powered pacemakers are no longer being manufactured and
virtually all have been replaced by lithium units. A/B MACs still receiving claims for
monitoring such units should continue to apply the guidelines published in 1980 to those
units until they are replaced.
There are two general types of pacemakers in current use - single-chamber pacemakers
which sense and pace the ventricles of the heart, and dual-chamber pacemakers which
sense and pace both the atria and the ventricles. These differences require different
monitoring patterns over the expected life of the units involved. One fact of which A/B
MACs should be aware is that many dual-chamber units may be programmed to pace
only the ventricles; this may be done either at the time the pacemaker is implanted or at
some time afterward. In such cases, a dual-chamber unit, when programmed or
reprogrammed for ventricular pacing, should be treated as a single-chamber pacemaker in
applying screening guidelines.
The decision as to how often any patient’s pacemaker should be monitored is the
responsibility of the patient’s physician who is best able to take into account the
condition and circumstances of the individual patient. These may vary over time,
requiring modifications of the frequency with which the patient should be monitored. In
cases where monitoring is done by some entity other than the patient’s physician, such as
a commercial monitoring service or hospital outpatient department, the physician’s
prescription for monitoring is required and should be periodically renewed (at least
annually) to assure that the frequency of monitoring is proper for the patient. Where a
patient is monitored both during clinic visits and transtelephonically, the A/B MAC
should be sure to include frequency data on both types of monitoring in evaluating the
reasonableness of the frequency of monitoring services received by the patient.
Since there are over 200 pacemaker models in service at any given point, and a variety of
patient conditions that give rise to the need for pacemakers, the question of the
appropriate frequency of monitoring is a complex one. Nevertheless, it is possible to
develop guidelines within which the vast majority of pacemaker monitoring will fall and
A/B MACs should do this, using their own data and experience, as well as the frequency
guidelines which follow, in order to limit extensive claims development to those cases
requiring special attention.
History
(Rev. 173, Issued: 09-04-14, Effective: Upon Implementation: of ICD-10, Implementation: Upon Implementation of ICD-10)
Provenance
- Source
- cms.gov
- Retrieved
- 2026-08-25
- Edition
- iom-2026-08-25
- Content hash
e1d76e6b34f74b5fc43fddc7fc665916408fe40deaa7647321f1f67ce6b92eb1
The link goes to the issuing authority’s own document — the one we read to produce this record. Where a source publishes whole titles rather than sections, your browser may need a moment to jump to the provision.
Unofficial copy of government-published law, reproduced from official sources with full provenance. Not an official publication; verify against official sources before relying on it in a filing. Records in the 'guidance' corpus, and only that corpus, are sub-regulatory (interpretive guidelines, survey procedures) and are not binding law. Validity bounds follow each jurisdiction's declared temporalBasis.