CMS Pub. 100-03, ch. 1, § 20.30
Microvolt T-Wave Alternans (MTWA)
A. General
Microvolt T-wave Alternans (MTWA) testing is a non-invasive diagnostic test that
detects minute electrical activity in a portion of the electrocardiogram (ECG) known as
the T-wave. MTWA testing has a role in the stratification of patients who may be at risk
for sudden cardiac death (SCD) from ventricular arrhythmias.
Within patient groups that may be considered candidates for implantable cardioverter
defibrillator (ICD) therapy, a negative MTWA test may be useful in identifying low-risk
patients who are unlikely to benefit from, and who may experience worse outcomes from,
ICD placement.
Spectral analysis (SA) is a sensitive mathematical method of measuring and comparing
time and the ECG signals. It requires specialized propriety electrodes to calculate minute
T-wave voltage changes. Software then analyzes these microvolt changes and produces a
report to be interpreted by a physician. The Modified Moving Average (MMA) method
uses a temporal domain in which T-wave alternans are assessed as a continuous variable
along the complete ECG. The MMA method of MTWA testing is performed using
standard ambulatory ECG equipment.
B. Nationally Covered Indications
Effective for dates of service on and after March 21, 2006, MTWA diagnostic testing is
covered for the evaluation of patients at risk for SCD, only when the SA method is used.
C. Nationally Non-Covered Indications
N/A
D. Other
Effective for dates of service on and after January 21, 2015, A/B MACs acting within
their respective jurisdictions may determine coverage of MTWA diagnostic testing for
the evaluation of patients at risk for SCD using all other methods.
(This NCD last reviewed January 2015.)
History
(Rev. 182, Issued: 05-22-15, Effective: 01-13-15, Implementation: 06-23-15)
Provenance
- Source
- cms.gov
- Retrieved
- 2026-08-25
- Edition
- iom-2026-08-25
- Content hash
5ff39c8e0c8876470b47a9335eca4d54d7e8e16b0e0d9a13597b25da7156d077
The link goes to the issuing authority’s own document — the one we read to produce this record. Where a source publishes whole titles rather than sections, your browser may need a moment to jump to the provision.
Unofficial copy of government-published law, reproduced from official sources with full provenance. Not an official publication; verify against official sources before relying on it in a filing. Records in the 'guidance' corpus, and only that corpus, are sub-regulatory (interpretive guidelines, survey procedures) and are not binding law. Validity bounds follow each jurisdiction's declared temporalBasis.